Measurement principle: Ultrasonic
Measurement range: DN25-DN6000
Flow range: 0.1~8 m/s
Flow accuracy: 1%
Temperature range: -40 ℃-60 ℃,-40 ℃-130 ℃
Input: DC8-36V V/AC85-264V
output: 4 ~ 20mA, RS485(Modbus RTU)








1. Product Introduction
Multiple Customization Options: Single-channel, dual-channel, and quad-channel options available, varying in accuracy; non-invasive installation, no pressure loss, adaptable to complex pipe diameters.
±1% Accuracy: Ensures accurate and reliable non-contact liquid flow measurement.
Universal Compatibility: Suitable for measuring various media from DN25 to DN6000.
Easy Installation: No pipe cutting required; installation does not affect production; suitable for flammable, explosive, and corrosive media pipelines; quick and convenient wall-mounted batch design; easy installation and commissioning, no professional personnel required.
Customizable Solutions: Tailor-made to specific industry or application needs.
2. Easy installation: no need to cut the pipe; installation will not affect production;
3. Suitable for flammable, explosive and corrosive medium pipeline;
4. Fast and convenient wall-mounted batch design;
5. Easy installation and debugging。
No
Name
Parameter
01
Measurement principle
Ultrasonic
02
Flow range
0.1~8 m/s
03
Accuracy
±1%
04
Power supply
DC8-36V/AC85-264V
05
Signal output
4 ~ 20mA,RS485(ModbusRTU)
06
Pipe diameter
DN25-6000
07
Medium
Water, foaming agent, diesel oil, methanol and other